meta data for this page
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| hw:server:proliant380eg8:ssacli [2021/09/16 10:03] – niziak | hw:server:proliant380eg8:ssacli [2021/10/10 20:46] (current) – niziak | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== ssacli ====== | ====== ssacli ====== | ||
| + | |||
| + | Source: [[https:// | ||
| <code bash> | <code bash> | ||
| Line 17: | Line 19: | ||
| ssacli ctrl slot=2 array all show detail | ssacli ctrl slot=2 array all show detail | ||
| </ | </ | ||
| + | |||
| + | ====== rescan for new drives ====== | ||
| + | |||
| + | '' | ||
| ====== cache ratio ====== | ====== cache ratio ====== | ||
| Line 33: | Line 39: | ||
| Show rebuild priority: | Show rebuild priority: | ||
| '' | '' | ||
| + | |||
| + | ====== switch to HBA mode ====== | ||
| + | <code bash> | ||
| + | ssacli ctrl slot=2 ld all delete | ||
| + | ssacli controller slot=2 modify hbamode=on | ||
| + | </ | ||
| + | |||
| + | |||
| ===== RAID5 ===== | ===== RAID5 ===== | ||
| Line 51: | Line 65: | ||
| ssacli ctrl slot=2 array B show detail | ssacli ctrl slot=2 array B show detail | ||
| + | # Force Linux to detect size change: | ||
| + | echo 1 > / | ||
| + | |||
| + | # echo 1 > / | ||
| + | # partprobe /dev/sdb | ||
| </ | </ | ||