meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
hw:server:proliant380eg8:ssacli [2021/09/16 11:21] niziakhw:server:proliant380eg8:ssacli [2021/10/10 20:46] (current) niziak
Line 39: Line 39:
 Show rebuild priority: Show rebuild priority:
 ''ssacli ctrl slot=2 modify rp=?'' ''ssacli ctrl slot=2 modify rp=?''
 +
 +====== switch to HBA mode ======
 +<code bash>
 +ssacli ctrl slot=2 ld all delete
 +ssacli controller slot=2 modify hbamode=on
 +</code>
 +
 +
  
 ===== RAID5 ===== ===== RAID5 =====
Line 59: Line 67:
 # Force Linux to detect size change: # Force Linux to detect size change:
 echo 1 > /sys/class/scsi_disk/0\:1\:0\:1/device/rescan echo 1 > /sys/class/scsi_disk/0\:1\:0\:1/device/rescan
 +
 +# echo 1 > /sys/block/sdb/device/rescan
 +# partprobe /dev/sdb
 +
 </code> </code>