meta data for this page
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| vm:proxmox:ceph:db:move_db_disks [2026/10/21 10:19] – niziak | vm:proxmox:ceph:db:move_db_disks [2026/10/21 11:23] (current) – niziak | ||
|---|---|---|---|
| Line 81: | Line 81: | ||
| lvextend -l +100%FREE ceph-db/db | lvextend -l +100%FREE ceph-db/db | ||
| lvchange -ay / | lvchange -ay / | ||
| + | |||
| + | # restore owner and re-creates symlinks: | ||
| + | ceph-volume lvm activate --all | ||
| </ | </ | ||
| Line 92: | Line 95: | ||
| systemctl start ceph-osd@3.service | systemctl start ceph-osd@3.service | ||
| ceph osd unset noout | ceph osd unset noout | ||
| + | </ | ||
| + | |||
| + | Resize LV without migrating DB to HDD and back is possible: | ||
| + | <code bash> | ||
| + | |||
| + | # restore owner and re-creates symlinks: | ||
| + | ceph-volume lvm activate --all | ||
| + | |||
| + | # expand BlueFS | ||
| + | ceph-bluestore-tool bluefs-bdev-expand --path / | ||
| + | |||
| + | # Verify new size: | ||
| + | ceph-bluestore-tool show-label --dev /dev/dm-1 | ||
| + | ceph tell osd.5 bluefs stats | ||
| </ | </ | ||